Standards
TVG-05 Kombi/-06 electronic ballasts meet the following standards:
| Typ: |
|
UIC 555-1 |
| Input voltage: |
|
Primary RIA 12 |
EMC and interferance resistance: |
|
ENV 50121-3-2 |
| Vibration test: |
|
per DIN 40046; EN 50155; IEC 68-2-6; IEC 571-1; DIN/VDE 0115 |
Technical data
 |
 |
Input voltages: 18, 24, 36, 48, 72, 110Vdc |
 |
|
Input voltage range: + 30 % (e.g. 16,8 ... 32Vdc for a 24V battery) |
 |
|
Operating frequency: about 26 kHz |
 |
|
Output voltage: Sine wave |
 |
|
Overall efficiency: typical 85% |
 |
|
Preheating time: 1 sec. per UIC 555-1 2 sec. standard Swiss setting |
 |
|
Switch lifetime: > 500'000 (typical 36W) |
 |
|
Ambient temperature range: -30 oC...+80 oC |
 |
|
Max. permissible input voltage: 1.5 x Unom during 10 min. |
 |
|
Enclosure protection: IP 50 |
 |
|
Vibration test: per DIN 40046-8 (5g) |
 |
|
Fuses: externally accessible |
 |
|
Weight: 0.260kg |
 |
|
Connectors: Faston 6,3 mm tabs Spring jaws Wago |
 |
|
Cable length: max. 5 m from TVG to lamp |
 |
|
Installation: Can be installed in or on the lamp housing (if installed outside the housing, always provide suitable grounding!) |
Dimmable version available on request.
Contact us for an offer at no obligation!