TVG-05 Kombi/-06 electronic ballasts meet the following standards:

Typ:   UIC 555-1
Input voltage:   Primary RIA 12
EMC and interferance
resistance:
  ENV 50121-3-2
Vibration test:   per DIN 40046; EN 50155;
IEC 68-2-6; IEC 571-1;
DIN/VDE 0115

Technical data
Input voltages:
18, 24, 36, 48, 72, 110Vdc
Input voltage range:
+ 30 % (e.g. 16,8 ... 32Vdc for a 24V battery)
Operating frequency:
about 26 kHz
Output voltage:
Sine wave
Overall efficiency:
typical 85%
Preheating time:
  • 1 sec. per UIC 555-1
  • 2 sec. standard Swiss setting
  • Switch lifetime:
    > 500'000 (typical 36W)
    Ambient temperature range:
    -30 oC...+80 oC
    Max. permissible input voltage:
    1.5 x Unom during 10 min.
    Enclosure protection:
    IP 50
    Vibration test:
    per DIN 40046-8 (5g)
    Fuses:
    externally accessible
    Weight:
    0.260kg
    Connectors:
  • Faston 6,3 mm tabs
  • Spring jaws Wago
  • Cable length:
    max. 5 m from TVG to lamp
    Installation: Can be installed in or on the lamp housing
    (if installed outside the housing, always provide
    suitable grounding!)

    Dimmable version available on request.